AI servers, GPU infrastructure and campus services
GRECO combines AI server and infrastructure supply with energy-first campus development. Start with the hardware platform or compute facility your project needs, then compare configuration, cooling, support and delivery requirements.
For projects in the United States and Canada, plan the delivery destination, local support coverage and site requirements alongside the equipment itself.
Choose your server or infrastructure path
Dell PowerEdge servers
Explore AI/GPU, rack, tower and edge platforms, with model specifications and pricing considerations.
Explore the platformLenovo ThinkSystem & ThinkAgile
Compare server families, workload fit, configuration planning and manufacturer product guides.
Explore the platformGPU colocation & compute
Plan rack power, liquid cooling, network connectivity and the facility responsibilities around your hardware.
Explore the platformServer parts and configuration planning
For memory, storage, network adapters and GPU accelerators, begin with the manufacturer part number and exact server model. Check platform generation, firmware, power and cooling compatibility, and support eligibility. Define required quantities and acceptable substitutions before comparing component costs.
Six campus products. One megawatt.
A megawatt of compute also produces recoverable heat and storage flexibility. GRECO's campus model combines compute, energy and heat recovery, with individual products or an integrated stack.
Powered Shell
The building, powered and cooled — you bring the compute
A long-term lease or capacity agreement for a powered, cooled shell — the slowest and hardest part of a data centre to get right. You bring your own racks and hardware; we deliver the site, the power and the thermal train, and take the interconnection risk off your critical path.
AI Compute Capacity
Powered, liquid-cooled rack capacity
Lease liquid-cooled rack capacity in a campus that arrives with its own generation — no interconnection queue between you and go-live. Roughly 150 kW racks ship today and our halls are designed around them, with the power and cooling architecture engineered for the 600 kW to 1 MW class and 800 VDC distribution as that hardware reaches market.
Recovered Heat
50 °C metered into district energy
Liquid cooling captures compute heat at 45–48 °C on the return loop; plate heat exchangers lift it to 50 °C that fourth-generation district energy needs. An Energy Transfer Station forms the metering boundary with the utility. This is the product almost every other operator throws away.
Behind-the-Meter Power
Firm, dispatchable, on your side of the meter
On-site generation firmed by grid-scale storage, delivering 24/7 dispatchable baseload independent of grid congestion. Where clean utility power is available we use it; where it is not — or where the queue is years long — the campus generates its own.
Grid Services
Storage and load flex the utility can dispatch
Lithium blocks deliver fast power for ride-through and grid services; vanadium flow adds long-duration capacity with no cycle degradation. Together they let the campus shed load in seconds when the grid calls — turning a large new load into a grid asset rather than a grid burden.
Megawatt EV Charging
Fleet-scale charging on campus power
Campus power infrastructure supports megawatt-class charging for commercial fleets, with vehicle-to-grid capability — using the same behind-the-meter generation and storage that serves the compute halls.
Beyond the campus
These aren’t co-products of a megawatt — they’re sold on their own, to projects that have nothing to do with our sites.
Manufacturing & OEM Capacity
GRECO-branded BESS, ETS and power-system integration
GRECO-branded battery storage, energy transfer stations and power-system integration — including licensing and assembly. The same equipment we engineer into our own campuses, available to projects that aren’t ours.
IT Hardware & Rack Supply
AI server, rack and GPU infrastructure
GRECO is a Dell managed service provider, supplying the full PowerEdge line — AI and GPU systems, rack, tower and rugged edge servers — specified against your workload, procured, racked and then operated as a managed fleet. Source the compute and the campus that powers it from one counterparty instead of stitching them together yourself.
What’s available where
Availability follows the site tier — availability is confirmed per campus at enquiry.
| Product | Urban Edge | Metro | Regional |
|---|---|---|---|
| Powered shell | Yes — small footprint | Yes | Yes — largest blocks |
| AI compute capacity | Inference / low-latency | Mixed | Training / bulk |
| Recovered heat | Strongest — dense heat customers | Good | Needs a host network |
| Behind-the-meter power | Limited | Yes | Core |
| Grid services | Yes | Yes | Strongest |
| Megawatt EV charging | Limited | Yes | Yes — land available |
Bundled, if it suits you
Four common shapes. Bundling isn’t a discount — it’s stacking, and it’s what makes firm dates and long terms work.
Powered Capacity
AI operators & colocation tenants
Compute + behind-the-meter power + resilience
Campus Thermal
District-energy utilities & municipalities
Metered 50 °C heat via the ETS
Grid Asset
The utility
Storage + demand response + dispatchable flex
Fleet Hub
Commercial fleet operators
Megawatt charging + V2G on campus power