Six products. One megawatt.
A megawatt of compute doesn’t only produce compute. It produces recoverable heat and storage flexibility too. So a GRECO campus sells the same energy more than once — to an AI operator, a neighbourhood energy utility and the grid — without any of them competing for it. Take one product, or take the stack.
And beyond the campus, we supply the equipment itself — GRECO-branded storage and energy transfer systems, and the AI hardware that fills the racks.
Powered Shell
The building, powered and cooled — you bring the compute
A long-term lease or capacity agreement for a powered, cooled shell — the slowest and hardest part of a data centre to get right. You bring your own racks and hardware; we deliver the site, the power and the thermal train, and take the interconnection risk off your critical path.
AI Compute Capacity
Powered, liquid-cooled rack capacity
Lease liquid-cooled rack capacity in a campus that arrives with its own generation — no interconnection queue between you and go-live. Roughly 150 kW racks ship today and our halls are designed around them, with the power and cooling architecture engineered for the 600 kW to 1 MW class and 800 VDC distribution as that hardware reaches market.
Recovered Heat
50 °C metered into district energy
Liquid cooling captures compute heat at 45–48 °C on the return loop; plate heat exchangers lift it to 50 °C that fourth-generation district energy needs. An Energy Transfer Station forms the metering boundary with the utility. This is the product almost every other operator throws away.
Behind-the-Meter Power
Firm, dispatchable, on your side of the meter
On-site generation firmed by grid-scale storage, delivering 24/7 dispatchable baseload independent of grid congestion. Where clean utility power is available we use it; where it is not — or where the queue is years long — the campus generates its own.
Grid Services
Storage and load flex the utility can dispatch
Lithium blocks deliver fast power for ride-through and grid services; vanadium flow adds long-duration capacity with no cycle degradation. Together they let the campus shed load in seconds when the grid calls — turning a large new load into a grid asset rather than a grid burden.
Megawatt EV Charging
Fleet-scale charging on campus power
Campus power infrastructure supports megawatt-class charging for commercial fleets, with vehicle-to-grid capability — using the same behind-the-meter generation and storage that serves the compute halls.
Beyond the campus
These aren’t co-products of a megawatt — they’re sold on their own, to projects that have nothing to do with our sites.
Manufacturing & OEM Capacity
GRECO-branded BESS, ETS and power-system integration
GRECO-branded battery storage, energy transfer stations and power-system integration — including licensing and assembly. The same equipment we engineer into our own campuses, available to projects that aren’t ours.
IT Hardware & Rack Supply
AI server, rack and GPU infrastructure
GRECO is a Dell managed service provider, supplying the full PowerEdge line — AI and GPU systems, rack, tower and rugged edge servers — specified against your workload, procured, racked and then operated as a managed fleet. Source the compute and the campus that powers it from one counterparty instead of stitching them together yourself.
What’s available where
Availability follows the site tier — availability is confirmed per campus at enquiry.
| Product | Urban Edge | Metro | Regional |
|---|---|---|---|
| Powered shell | Yes — small footprint | Yes | Yes — largest blocks |
| AI compute capacity | Inference / low-latency | Mixed | Training / bulk |
| Recovered heat | Strongest — dense heat customers | Good | Needs a host network |
| Behind-the-meter power | Limited | Yes | Core |
| Grid services | Yes | Yes | Strongest |
| Megawatt EV charging | Limited | Yes | Yes — land available |
Bundled, if it suits you
Four common shapes. Bundling isn’t a discount — it’s stacking, and it’s what makes firm dates and long terms work.
Powered Capacity
AI operators & colocation tenants
Compute + behind-the-meter power + resilience
Campus Thermal
District-energy utilities & municipalities
Metered 50 °C heat via the ETS
Grid Asset
The utility
Storage + demand response + dispatchable flex
Fleet Hub
Commercial fleet operators
Megawatt charging + V2G on campus power